大坝测压管观测资料分析在北邢家水库渗流安全评价中的应用  被引量:4

Application of dam piezometer pipe data analysis in seepage safety assessment of Beixingjia reservoir

在线阅读下载全文

作  者:季安[1] 姜葵红[1] 牟燕妮[1] 于文蓬[1] 兰昊[1] 

机构地区:[1]山东省水利勘测设计院,山东济南250013

出  处:《大坝与安全》2008年第5期33-36,共4页Dam & Safety

摘  要:通过对北邢家水库大坝测压管观测资料进行综合分析,结合日常检查及地质勘察资料,判断出部分坝段粘土心墙存在填筑不均匀与防渗性能差的质量问题,发现了部分坝段存在坝体上游水位长期高于库水位的渗流异常现象,并将测压管资料绘制的大坝浸润线与渗流计算的浸润线进行对比,对理论计算采用的渗透系数予以验证。By data analysis of dam piezometer pipe, combined with routine inspection and geological survey of Beixingjia reservoir, the quality problem of bad filling and high permeability of the clay core wall was found. Also, the problem that dam upstream water level was higher than reservoir water level exists at some dam blocks. This paper compared the measured phreatic line to caleulative phreatic line, and verified the seepage coefficient adopted in theory analysis.

关 键 词:测压管 渗流 浸润线 相关性 

分 类 号:TV698.1[水利工程—水利水电工程]

 