超超临界机组汽轮机带双列高压加热器热力性能试验的测量计算方法  

MEASUREMENT AND CALCULATION METHOD FOR THERMAL PERFORMANCE TEST OF ULTRA-SUPERCRITICAL UNIT WITH STEAM TURBINE EQUIPPED WITH DOUBLE-ROW HIGH-PRESSURE HEATERS

在线阅读下载全文

作  者:施延洲[1] 朱立彤[1] 姚啸林[1] 钟平[1] 安红心[1] 

机构地区:[1]西安热工研究院有限公司,陕西西安710032

出  处:《热力发电》2009年第1期27-30,共4页Thermal Power Generation

摘  要:针对带双列高压加热器的超超临界机组特点,分析了双列高压加热器水侧流量不平衡对计算结果的影响。实例计算表明,采用等流量分配的加热器热平衡方法完全满足机组性能考核试验标准。对试验条件和测点布置提出了具体要求。Directing against the features of ultra - supercritical unit equipped with double - row high - pressure(HP)feed - water heaters,the influence of unbalance flow rate in the water side of double- row HP heaters upon the calculated results has been analysed. Results of calculation in concrete examples show that the adoption of thermal balance method in heaters with equal flow rate distribution can fully satisfy the test standard of performance assessment for the units, and the requirements for test conditions and arrangement of measuring points have been put forward.

关 键 词:超超临界机组 双列高压加热器 汽轮机 性能考核 热力性能 

分 类 号:TK212[动力工程及工程热物理—动力机械及工程]

 