作 者:刘永丹[1,2] 刘海浪[2] 王宝健[2] 陈一胜[1]
机构地区:[1]兰州理工大学材料科学与工程学院,甘肃兰州730050 [2]江西理工大学材料与化学工程学院,江西赣州341000
出 处:《机械工程材料》2009年第1期70-72,共3页Materials For Mechanical Engineering
摘 要:将X65钢放在高压釜内于60~150℃、1MPa的CO2酸性溶液中进行72h腐蚀,用XRD、EPMA、SEM和失重法等方法分析了腐蚀产物的形貌、物相组成和腐蚀速率。结果表明:X65钢在60,90,120和150℃的腐蚀速率分别为10.97,3.70,8.37和18.97mm·a-1;60℃时在腐蚀表面不生成FeCO3保护膜,腐蚀较严重;90℃时生成细小致密的FeCO3保护膜,腐蚀较轻;120℃时生成细小松散的FeCO3保护膜,腐蚀较严重;而150℃时生成粗大不紧密的FeCO3保护膜,所以腐蚀最严重。X65 steel specimens were tested in an acidic solulion containing CO2 with a pressure of 1 MPa at 60 -150 ℃ for 72 h in an autoclave. XRD, EPMA, SEM and weight-loss methods were used to analyze the corrosion products and corrosion rates. The results showed that the corrosion rates at 60 ℃, 90 ℃, 120 ℃ and 150 ℃ were 10. 97, 3. 70, 8. 37 and 18. 97 mm · a- 1 respectively. Protective films of FeCO3 were not generated at 60 ℃ resulting in serious corrosion. Fine and compact protective fihns of FeCO2 were formed at 90 ℃ and reduced the corrosion rate markedly. The FeCOa films were relatively fine but scattered at 120 ℃ and were coarse and loose at 150 ℃ and thus increased the corrosion rate.
分 类 号:TG142.41[一般工业技术—材料科学与工程] TG172.6[金属学及工艺—金属材料]