高碳铬铁中磷、硅、锰的电感耦合等离子体原子发射光谱测定方法的研究  被引量:9

Determination of Phosphorous, Silicon and Manganese in High Carbon Ferro Chrome by Inductively Coupled Plasma -Atomic Emission Spectrometry

在线阅读下载全文

作  者:刘肖芳 汪宇卫 

机构地区:[1]上海进出口商品检验局,上海200092

出  处:《分析化学》1998年第4期474-476,共3页Chinese Journal of Analytical Chemistry

摘  要:采用过氧化钠在石墨坩埚中熔融分解样品,硝酸酸化后直接用ICP测定。磷、硅、锰的测定范围分别为0.005%~0.075%、0.30%~6.00%、0.03%~2.00%;相对标准偏差RSD≤6.0%。A method for determination of phosphorous, silicon and manganese in high carbon ferro chrome by inductively coupled plasma atomic emission spectrometry was studied. The sample was fused and dissolved with sodium peroxide in graphite crucible, acidified'by nitric acid and then directly analyzed by inductively coupled plasma atomic emission spectrometry. The detection ranges for phosphorous, silicon and manganese are 0. 005% ~0. 075%, 0. 30% ~6. 00% and 0. 03% ~2. 00%, respectively. The relative standard deviation of this method is less than 6%. The recommended method not only proved to be simple and rapid but showed satisfying accuracy as well.

关 键 词:高碳铬铁    ICP-AES 测定 

分 类 号:TG144[一般工业技术—材料科学与工程]

 