检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:孙星慧[1] 倪榕[1] 林文洪[1] 谭建明[1]
机构地区:[1]南京军区福州总医院泌尿外科,福州350025
出 处:《临床泌尿外科杂志》2008年第12期933-934,共2页Journal of Clinical Urology
摘 要:目的:推广一种有效的经膀胱镜双J管逆行插管方法。方法:对一组需要留置双J管引流的患者,分别采用传统置管方法和改良置管方法进行插管,比较两组置管成功率及插管时间。结果:对照组8例采用传统置管法,只有4例一次成功,成功率50%,耗时15~60min,平均(25±3.5)min;实验组25例/次采用改良置管法,24例/次置管成功,成功率96%,置管需时5~15min,平均(8±2)min。两组对比,改良方法明显优于传统方法(P<0.05)。结论:改良双J管置管方法操作时间短,成功率高,患者痛苦小,值得推广。Objective: To evaluate a new method for retrograde double J tube placement by cystoscope. Methods: Two groups of patients were placed double J tube retrogradly by cystoscope using traditional method and new method, respectively. The success rate and operating time were compared. Results: In eight patients of control group, double J tube were retrocathetered using traditional method, only 4 patients (50% )succeed, taking 15--60 rain(average 25±3.5 min) ; But in the new method group with 25 patients/times, 24 of them (96%) were technically successful, which took 5--15 min (average 8 ± 2 rain). Conclusions:This new technique can reduce general anaesthetic use, take less time, and is more effective and successful.