电化学絮凝与化学絮凝法联合处理油田污水的实验分析  被引量:9

Experimental analysis of oily wastewater treatment by electrolytic and chemical flocculation technology

在线阅读下载全文

作  者:刘立新[1] 赵晓非[1] 胡仪[2] 阎晶红[1] 胡振峰[1] 

机构地区:[1]大庆石油学院化学化工学院,黑龙江大庆163318 [2]北京师范大学生命科学学院,北京100875

出  处:《大庆石油学院学报》2009年第1期49-51,122,共3页Journal of Daqing Petroleum Institute

基  金:黑龙江省科技攻关项目(GZ06A403);黑龙江省教育厅科学技术研究项目(11513008)

摘  要:为减少絮凝剂的用量,分析采用电化学絮凝与化学絮凝法联合处理油田聚驱污水.通过正交实验确定电化学絮凝的最佳实验条件:电极板间距为9 mm,电解时间为16 min,电流密度为1 000 A/m2.电化学絮凝与絮凝剂PAC联合处理聚驱污水后,可使PAC的加剂质量浓度减小660 mg/L,上清液透光率接近99.0%;电化学絮凝与絮凝剂CPAM联合处理聚驱污水后,可使CPAM的加剂质量浓度减小192 mg/L,上清液透光率接近99.0%.且经联合处理后,污水中絮体量小,易于后续过程处理.Polymer flooding technology has been used successfully in some oil fields,but the produced water is more difficult to treat than that from water flooding.In order to save the dosage of flocculent,the electrolytic flocculation united with chemical flocculation was studied.The optimal experimental condition of electrolytic flocculation was determined by orthogonal test: the space between electrodes was 9 mm,the electrolytic time was 16 min,the current density was 1 000 A·m-2.After treating the wastewater of polymer flooding by electrolytic flocculation and PAC,the dosage of PAC can save nearly 700 mg·L-1,and the light transmission of the supernatant liquid was nearly 99.0%.After treating the wastewater of polymer flooding by electrolytic flocculation and CPAM,the dosage of CPAM can save nearly 200 mg/L,and the light transmission of the supernatant liquid was nearly 99.0%.The floc was less,this would be propitious to later treatment.

关 键 词:电化学絮凝 化学絮凝 油田污水 处理 

分 类 号:X703[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象