气相色谱法测定头孢哌酮粉针剂中溶媒残留量  被引量:3

Determination of Solvent Residue in Cefoperazone Sodium for Injection by Gas Chromatography

在线阅读下载全文

作  者:郭国岭[1] 姜春刚[1] 张伟新[1] 

机构地区:[1]丽珠集团丽珠制药厂

出  处:《中国药科大学学报》1998年第2期112-114,共3页Journal of China Pharmaceutical University

摘  要:建立了头孢哌酮粉针剂中残留溶媒异丙醇的测定方法。用无水乙醇提取样品,以正丙醇为内标物,用GDX-102填充柱分离。异丙醇浓度范围在3.19×10-4~1.28×10-3g/ml存在较好的线性关系,r=0.9998,方法回收率94.4%。This paper describes a method for determination of solvent residue in cefoperazone sodium for injection. Propanol was used as internal standard. The analysis was performed on GDX102 column. Over the concentration range from 3.19×10-4 to 1.28×10-3 g/ml of 2propanol, the calibration curve was liner with regression equation Y=1115.25X+0.006178(r=0.9998). The average recovery was 94.4%.

关 键 词:头孢哌桐 溶媒残留量 异丙醇 气相色谱法 针剂 

分 类 号:R978.11[医药卫生—药品] R927.1[医药卫生—药学]

 