检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:居红芳[1] 徐桦[1] 朱慧[1] 周培芳[1] 钱敏芳[1] 叶晓君[1]
机构地区:[1]常熟理工学院化学与材料工程系江苏省新型材料重点实验室,江苏常熟215500
出 处:《高校化学工程学报》2009年第1期12-17,共6页Journal of Chemical Engineering of Chinese Universities
基 金:江苏省新型材料重点实验室项目(06KFJJ002)
摘 要:水-异丙醚-苯酚体系的研究在工业上和环境保护上具有重要意义,但至今未见到液液平衡(LLE)数据的报导。今报导了这一系统在两个工作温度的LLE数据。为了寻找萃取剂异丙醚的替代物,我们同时进行了水-异丁醇-苯酚体系的液液平衡研究。在常压下使用GC-14B气相色谱仪,测定了319K和329K时水-异丙醚-苯酚体系的液液平衡(LLE)数据以及水-异丁醇-苯酚体系在319K和333K时的LLE数据。用内标法测定了这些体系中除水以外的各组分浓度。在水-异丙醚-苯酚体系中,异丙醚测量的根均方误差为1.4%;苯酚测量的根均方误差为4.6%。在水-异丁醇-苯酚体系中,异丁醇测量的根均方误差为3.1%;苯酚测量的根均方误差为4.6%。文中给出了上述四个等温截面的LLE数据,同时也给出了相应示意图。2003年我们用工作曲线法(外标法)给出了水-异丙醚-苯酚在319K的等温截面图。两者比较,总体上是类似的,但内标法结果更可靠。这次的研究,还纠正了当时的一个错误估计。对于水-异丁醇-苯酚体系的液液平衡研究表明,异丁醇也是从废水中萃取苯酚的良好萃取剂。但是异丁醇的再生及其循环利用并不如异丙醚那样容易。The study of water-isopropyl ether-phenol (H2O-(CH3)2CHOCH(CH3)2-C6H5OH) system is a matter of importance for industrial production and environment protection, but there is no report dealing with the liquid-liquid equilibrium (LLE) data of this system up to now. This paper reports the LLE data of this system under normal pressure and at two working temperatures of 319.15 K and 329.15 K, and they were measured by using GC-14B gas chromatograph. In order to search the substitute for extractant isopropyl ether, the LLE data of water-isobutanol-phenol (H2O-(CH3)2CHCH2OH-C6H5OH) system under normal pressure and at 319.15 K, and 333.15 K were also studied by using the GC-14B gas chromatograph too. In the water-isopropyl ether-phenol (W-IE-P) system, the root-mean-square error of measurement for isopropyl ether is 1.4 %, and that for phenol is 4.6%. In the water-isobutanol-phenol (W-IB-P) system, the root-mean-square error of measurement for isobutanol is 3. 1%, and that for phenol is 4.6%. The obtained LLE data mentioned above and their corresponding isothermal section diagrams (ISD) were given in this paper. In the year 2003, we have published an isothermal section diagram of W-IE-P system at 319.15 K, which was established on the base of data measured by working curve method. Comparing the ISD of W-IE-P system obtained by working curve method with that obtained bv inner-scaling method in this paper, both the ISD feathers are similar as a whole, but the results obtained by inner-scaling method are more reliable; and according to the results obtained by inner-scaling method, one previous estimation in the paper published in 2003 was corrected. The experiments of W-IB-P system show that the isobutanol is also a good extractant for extracting phenol from waste water, but the regeneration and recycle application of the isobutanol are not as easy as that of isopropyl ether.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.112