2007年南宁市城区部分旅店客房空气质量调查  被引量:3

Investigation on Indoor Air Quality in Hotels in Nanning City in 2007

在线阅读下载全文

作  者:苏萍[1] 陆丽珍[1] 覃竟亮[1] 

机构地区:[1]广西壮族自治区南宁市疾病预防控制中心,广西南宁530011

出  处:《预防医学论坛》2009年第1期38-39,共2页Preventive Medicine Tribune

摘  要:[目的]了解南宁市城区旅店客房的空气质量,探讨影响空气细菌总数的有关因素,为提高旅店客房空气质量提供参考依据。[方法]2007年7~12月,在南宁市城区选择中小型旅店85家,对242间客房进行检测。[结果]检测242间客房,细菌总数2~178个/皿,中位数为59.31个/皿,合格的62间,合格率为25.62%。细菌总数合格率,7~8月、9~10月、11~12月分别为34.78%、15.93%、32.43%(P〈0.01或P〈0.05),相对湿度50%~69%、70%以上的分别为16.67%、25.73%(P〉0.05),有空调的、无空调的分别为26.44%、17.11%(P〉0.05),可吸入尘含量〈0.05mg/m3的和≥0.05 mg/m3的分别为28.02%、11.84%(P〈0.05)。[结论]南宁市城区部分旅店客房空气质量较好,空气细菌总数合格率受到季节和可吸入尘含量的影响。[Objective]To understand indoor air quality in hotels in Nanning city,explore the related factors that influencing the total amount of bacteria,provide.scientific basis for improving the indoor air quality in hotels. [Methods]242 rooms from 85 middle and small-sized hotels were tested in Nanning city from July to December,2007. [Results]Of the 242 rooms tested,the total amount of bacteria was 2-178 per culture dish,the median was 59.31 per culture dish. The qualified rate was 25.62 %. The qualified rate of total amount of bacterial was 34. 78 %,15.93 % and 32.43 % from July to August, September to October and November to December( P d0. 01 or P d0. 05). Relative humidity of 500/00-69 % and 70% ac- counted for 16. 67%,25.73% ( P 〉0.05). It accounted for 26.44% ,17. 11% in room with air-conditioner and in room without air-conditioner. The content of respirable dust of 〈0. 05 mg/m3 or ≥0.05 mg/m3 in room accounted for 28.02 % and 11.84 % respectively( P 〈0.05). [Conclusion]Indoor air quality in hotels in Nanning city was good, the qualified rate of total amount of bacteria was affected by the changes of seasons and respirable dust.

关 键 词:旅店客房 空气细菌总数 可吸入尘 影响因素 

分 类 号:R126.4[医药卫生—环境卫生学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象