对二等标准水银温度计测量不确定度的探讨  被引量:2

On the Given Uncertainty in the Calibration Regulation of Grade Ⅱ Standard Mercury Thermometers

在线阅读下载全文

作  者:张金涛[1] 张哲[1] 张克 

机构地区:[1]中国计量科学研究院热工所,北京100013 [2]北京计量测试研究院,北京100013

出  处:《计量学报》2008年第B09期226-229,共4页Acta Metrologica Sinica

摘  要:比较分析了我国《二等标准水银温度计检定规程》、美国国家标准技术研究院关于参考水银温度计测量不确定度评定的文献和《二等标准水银温度计全国比对报告》关于测量不确定度的规定值及评定结果,并在参考不确定度表述指南基础上,说明了《二等标准水银温度计检定规程》在某些温度区间上规定的不确定度值有可能过小,存在不合理之处。Referring to the Guide to the Expression of Uncertainty in Measurement of ISO, the given measurement uncertainty by the calibration regulation of grade Ⅱ standard mercury thermometers, the estimated measurement uncertainty in the literatures of National Institute of Standards and Technology (NIST), and the estimated measurement uncertainty for thermometers used in the national comparison of grade Ⅱ standard mercury thermometers, are compared. The comparison indicates that the given uncertainty by calibration regulation of the grade Ⅱ standard mercury thermometers may be unreasonable small.

关 键 词:计量学 标准水银温度计 温度计检定规程 温度计测量不确定度 