检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:窦小晶 安翠翠[2] 朱海涛 张源斌[2] 乌鹏涛 何卓 高磊
机构地区:[1]西北西安输变电运行公司,西安710048 [2]西安交通大学电气工程学院,西安710049 [3]西北兰州输变电运行公司,兰州730050
出 处:《电瓷避雷器》2009年第1期42-46,共5页Insulators and Surge Arresters
摘 要:针对电气化铁路通信机房接地体的特殊运行环境受到的电磁干扰,设计了一套接地电阻在线监测系统。采用变频法测量接地电阻,将辅助电压极置于接地体与辅助电流极之间距离的0.59处,可以精确地测量接地电阻的大小,减少工作量;应用FIR滤波与FFT插值的抗干扰方案,使得沿线机房接地电阻在不断电的情况下实现精确的在线监测。应用该系统对电气化铁路通信机房接地电阻进行了现场实际测量,结果表明,该系统在电气化铁路强电磁干扰环境下能准确测量,可靠工作。Aimed at electromagnetic interference occurring at grounding object in communication station of electric railway under specific service conditions, an on-line monitoring system was developed. Using frequency converting technology, the accurate grounding resistance can be easily measured with a auxiliary voltage electrode installed at 0.59 times the distance between the grounding object and the auxiliary current electrode. Using the anti-interference solution with FIR filter and FFT interpolation, accurate on-line monitoring and measuring of grounding resistance of station can be realized. Site measurement of station grounding resistance was conducted, which proved accurate measurement with the developed system under severe EM interference of electric railway.