支铰钢梁的振动时效与残余应力分析  被引量:2

Analysis of Vibratory Stress Relief and Residual Stress on Trunnion Steel Girder

在线阅读下载全文

作  者:胡木生[1] 梅燕[2] 韩志刚[1] 倪国胜[1] 

机构地区:[1]水利部水工金属结构质量检验测试中心,郑州450006 [2]二滩水电开发有限责任公司,成都610021

出  处:《理化检验(物理分册)》2009年第3期148-151,共4页Physical Testing and Chemical Analysis(Part A:Physical Testing)

摘  要:为消除刘家道口弧形闸门支铰钢梁焊接后的残余应力,通过有限元分析,确定了采用振动时效工艺,并对振动时效的效果进行了分析。结果表明:振动时效方案可有效消除钢梁的残余应力,为同类工程消除残余应力提供了范例和经验。According to theory analysis, the vibratory stress relief (VSR) technique was used on trunnion steel girder of pivoted gate in Liujiadaokou water complex project, which helps eliminate the residual stress. The effect of VSR was analyzed. The results showed that the residual stress on girder was eliminated effectively by VSR technique which validated by finite element method. It provided important experience for other projects.

关 键 词:支铰钢梁 振动时效 残余应力 

分 类 号:TG115.9[金属学及工艺—物理冶金]

 