检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈飒英[1] 周良鸿[1] 刘培嫦[1] 周湘[1] 王志新[1]
机构地区:[1]北京中日友好医院,100029
出 处:《新生儿科杂志》1998年第1期15-16,33,共3页The Journal of Neonatology
摘 要:为建立新生儿呼吸窘迫综合征的早期快速诊断方法,采用安定小泡试验检测出生3小时之内的新生儿胃液96例。RDS组14例和正常新生儿组82例安定小泡数量分别为3.82±553个/mm2和133.85±8291个/mm2,两组比较差异非常显著(P<0.01)。特异性为89.03%,灵敏度为92.86%。安定小泡数量与RDS的重症程度呈正相关关系(r=0.648,P<0.05)。我们认为安定小泡试验方法简单,迅速,灵敏度高,具有极高的临床应用价值。可以作为RDS的早期快速诊断方法。To establish a rapid detection method for diagnosis of respiratory distress syndrorne(RDS), we used stable microbubble test to detect 96 cases of gastric aspirate within 3 hoursafter birth. The results showed that 14 RDS were 3. 82±5. 53mm2, 82 normal infants were133. 85 ± 82. 91/mm2, Sensitivity was 92. 86%, specifity was 89. 03%. There was a goodpositive correlation between the severity of RDS and the numbers of stable microbubbles. Itis suggested that stable microbubble test is simple, rapid, inexpensive and high sensitivity.It could be used as a method for diagnosing RDS