HPLC法测定双氯芬酸钾片有关物质的探讨  被引量:1

Determination of Related Substances in Diclofenac Potassium Tablets by HPLC

在线阅读下载全文

作  者:石晶萍[1] 赵沈娟[1] 

机构地区:[1]扬子江药业集团质量管理部,江苏225321

出  处:《中国药品标准》2009年第1期50-52,共3页Drug Standards of China

摘  要:目的:探讨影响HPLC法测定双氯芬酸钾片有关物质的因素。方法:将双氯芬酸钾片在不同的试验条件下分别用水、甲醇两种溶剂溶解后测量有关物质。结果:双氯芬酸钾片水溶液光稳定性差,有关物质随光照时间增加而升高;双氯芬酸钾片甲醇溶液光稳定性好。结论:现行药品标准中双氯芬酸钾片中有关物质测定方法不合理,须进行修订。Objecitve: Study on determination of related substances in Diclofenac Potassium Tablets by HPLC. Method : Comparing the contents of related substances of Diclofenac Potassium Tablets in water and methanol. Results:Diclofenac Potassium Tablets is not stable in water, the content of related substances increase with the light time, methanol solution is more stable. Conclusion : The method of the state drug specification to determinate related substances of Diclofenac Potassium Tablets in water solution is unreasonable and should be adjusted.

关 键 词:HPLC 双氯芬酸钾片 有关物质 