摘 要:目的:计算192Ir吸收剂量率随角度的变化以及吸收剂量随径向距离的变化。方法:根据三维希弗(Sievert)剂量积分公式,利用蒙特卡罗积分方法计算了microSelectron-HDR192Ir放射源的剂量角度分布。结果:根据计算结果得到了吸收剂量随角度变化以及吸收剂量变化,并将计算结果和其他结果进行比较,结果发现是一致的。结论:蒙特卡罗积分方法计算192Ir放射源的剂量角度分布方法简单,易于实现,结果可靠。Objective: Absorbed dose vs polar angle and radial distance were calculated. Methods: Based on Sievert Integration, absorbed dose vs polar angle and radial distance ofmicroSelectron-HDR 192Ir were calculated using Monte Carlo method. Results: We could know absored dose vs polar angle and radial distance of microSelectron- HDR 192Ir ,and the calculated results were compared with others, they were in good agreement. Conclusions: Monte carlo method for calculating absored dose vs polar angle and radial distance of microSelectron-HDR 192Ir was a simple and reliable method.