Percutaneous aortic valve replacement using a W-model valved stent: a preliminary feasibility study in sheep  被引量:8

Percutaneous aortic valve replacement using a W-model valved stent: a preliminary feasibility study in sheep

在线阅读下载全文

作  者:BAI Yuan ZONG Gang-jun WANG Yan-yan JIANG Hai-bin LI Wei-ping WU Hong ZHAO Xian-xian QIN Yong-wen 

机构地区:[1]Department of Cardiology Changhai Hospital, Second Military Medical University, Shanghai 200433, China [2]Department of Ultrasonography, Changhai Hospital, Second Military Medical University, Shanghai 200433, China [3]Department of Cardiology, 101 Hospital of PLA, Wuxi, Jiangsu 210044, China [4]Department of' Internal' Medicine, Zhongshan Hospital, Fudan University, Shanghai 200032, China

出  处:《Chinese Medical Journal》2009年第6期655-658,共4页中华医学杂志(英文版)

摘  要:Background Percutaneous aortic valve replacement is a promising strategy in the treatment of patients with aortic valve stenosis. And many kinds of valved stents have been implanted in selected patients worldwide. However, the clinical experience is still limited. We developed a W-model valved stent and evaluated the feasibility and safety of percutaneous implantation of the device in the native aortic valve position.Methods A self expanding nitinol stent with W-model, containing porcine pericardium valves in its proximal part, was implanted in six sheep by means of a 14 French catheter through the right common iliac artery under guidance of fluoroscopy. During stent deployment the original aortic valve was pushed against the aortic wall by the self expanding force of the stent while the new valve was expanded. These sheep were followed up shortly after procedure with supra-aortic angiogram and left ventriculography. Additionally, one sheep was sacrificed after the procedure for anatomic evaluation.Results It was possible to replace the aortic valve in the beating heart in four sheep. The procedure failed in two sheep due to coronary orifice occlusion in one case and severe aortic valve regurgitation in the other case. One sheep was killed one hour after percutaneous aortic valve replacement for anatomic evaluation. There were no signs of damage of the aortic JntJma, or of obstruction of the coronary orifice,Conclusions Percutaneous aortic valve replacement with a W-model valved stent in the beating heart is possible. Further studies are mandatory to assess safety and efficacy of this kind of valved stent in larger sample size and by longer follow-up period.Background Percutaneous aortic valve replacement is a promising strategy in the treatment of patients with aortic valve stenosis. And many kinds of valved stents have been implanted in selected patients worldwide. However, the clinical experience is still limited. We developed a W-model valved stent and evaluated the feasibility and safety of percutaneous implantation of the device in the native aortic valve position.Methods A self expanding nitinol stent with W-model, containing porcine pericardium valves in its proximal part, was implanted in six sheep by means of a 14 French catheter through the right common iliac artery under guidance of fluoroscopy. During stent deployment the original aortic valve was pushed against the aortic wall by the self expanding force of the stent while the new valve was expanded. These sheep were followed up shortly after procedure with supra-aortic angiogram and left ventriculography. Additionally, one sheep was sacrificed after the procedure for anatomic evaluation.Results It was possible to replace the aortic valve in the beating heart in four sheep. The procedure failed in two sheep due to coronary orifice occlusion in one case and severe aortic valve regurgitation in the other case. One sheep was killed one hour after percutaneous aortic valve replacement for anatomic evaluation. There were no signs of damage of the aortic JntJma, or of obstruction of the coronary orifice,Conclusions Percutaneous aortic valve replacement with a W-model valved stent in the beating heart is possible. Further studies are mandatory to assess safety and efficacy of this kind of valved stent in larger sample size and by longer follow-up period.

关 键 词:PERCUTANEOUS aortic valve valved stent BIOPROSTHESIS 

分 类 号:R54[医药卫生—心血管疾病]

 