微电解—Fenton—SBR工艺处理皮革废水  被引量:15

Treatment of tannery wastewater by microelectrolysis-Fenton-SBR process

在线阅读下载全文

作  者:周作明[1] 李艳[1] 荆国华[1] 孙亮[1] 

机构地区:[1]华侨大学环境工程系,福建厦门361021

出  处:《工业水处理》2009年第3期62-64,共3页Industrial Water Treatment

基  金:福建省科技计划重大基金项目(2005HZ03-3);福建省自然科学基金项目(D0710019)

摘  要:采用微电解—Fenton—SBR工艺处理皮革废水,考察了各处理单元的最佳工艺参数及连续运行时的处理效果。结果表明:在进水pH为3,微电解反应时间为2 h,H2O2投加量3 mL/L,SBR曝气10 h的条件下,微电解—Fenon—SBR的运行效果最好,处理后的皮革废水最终出水水质可达到污水综合排放二级标准(GB 8798—1996)。Microelectrolysis-Fenton-SBR process has been applied to the treatment of tannery wastewater. The effects of operational parameters and the continuous running efficiency are investigated. The optimal operational parameters are as follows: when the influent pH is 3, treating time 2 h for microelectrolysis process, dosage of H2O2 3 ml/L and aeration time for SBR 10 h, the running efficiency of this process is the best. After treated, the effluent water quality of the tannery wastewater can meet the requirements of the Second Grade of Wastewater Discharge Standard(GB 8798--1996).

关 键 词:皮革废水 微电解 FENTON氧化 序批式反应器 

分 类 号:X703.1[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象