检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:吴新振[1] 兰勇[1] 张智晟[1] 崔海荣[1]
机构地区:[1]青岛大学电气工程系,山东省青岛市266071
出 处:《电网技术》2009年第7期55-58,共4页Power System Technology
基 金:国家自然科学基金资助项目(50747024)~~
摘 要:给出三角形接法三相自激异步发电机单相稳态建压时各参数满足的关系式,研究自激电容值对所建端电压的影响。基于对称分量法,通过矩阵分析推导发电机单相空载稳态运行时的回路阻抗,以回路阻抗为零作为异步发电机稳态运行的条件,采用坐标轮换优化方法求解方程并计算出空载电压值,所采用的方法编程简单且稳定性好。计算了不同自激电容下所建立的空载电压值,计算值与实验值吻合较好,证明了文中分析方法的有效性和准确性。The relationships among parameters of a delta-connected three-phase self-excited induction generator under single-phase steady-state operation are given to investigate the effect of self-excited capacitance on the built up terminal voltage. Based on the symmetrical component method and by means of matrix analysis, the loop impedance of induction generator under single-phase no-load steady-state operation is derived; regarding the zero loop impedance as the steady-state operation condition of induction generator, the equations are solved by alternative coordinate optimization and the value of no-load voltage is calculated. The applied calculation method is easy to program and stable. The no-load voltage values built up under various self-excited capacitances are calculated and the calculated values are close to experimental results, thus the effectiveness and accuracy of the proposed analysis method are validated.