检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:於仲义[1] 胡平放[1] 徐玉党[1] 袁旭东[1] 马友才[2]
机构地区:[1]华中科技大学 [2]中南建筑设计院
出 处:《暖通空调》2009年第3期98-101,9,共5页Heating Ventilating & Air Conditioning
摘 要:根据地埋管传热特性,提出了地埋管换热能效度概念。建立了竖直地埋管换热器的三维传热模型,模拟计算了地埋管换热器能效度在不同埋设深度条件下的分布。揭示了区段能效度的迁移特性,将地埋管换热区域沿埋设深度范围分为无效换热区域和有效换热区域,并给出了基于换热能效度的地埋管换热器长度设计方法。Based on the heat transfer characteristics the concept of energy efficiency degree. Establishes the of ground heat exchangers (GHEs), puts forward three-dimensional heat transfer model of vertical GHEs and simulates the energy efficiency degree distribution with different buried depths. Reveals migrating properties of the zonal energy efficiency degree, divides the heat transfer region of GHEs into the ineffective region and the effective region along the buried depth, and recommends some design methods of GHEs on the basis of the heat transfer energy efficiency degree.
分 类 号:TU833[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28