派瑞松乳膏中曲安奈德和硝酸益康唑的含量测定  被引量:6

Determination of Triamcinolone Acetonide and Econazole Nitrate in Triamcinolone Acetonide and Econazole Nitrate Cream by HPLC

在线阅读下载全文

作  者:刘百义[1] 

机构地区:[1]广西医科大学第五附属医院.柳州市人民医院,广西柳州545001

出  处:《中国药业》2009年第7期26-27,共2页China Pharmaceuticals

摘  要:目的建立派瑞松乳膏中曲安奈德和硝酸益康唑的含量测定方法。方法采用高效液相色谱(HPLC)法测定,色谱柱为Kromasil ODS-1柱(200mm×4.6mm,5μm),流动相为0.5%三乙胺(醋酸调节pH为3.0)-甲醇(50:50),检测波长为240nm,流速为1mL/min。结果曲安奈德和硝酸益康唑质量浓度分别在6.06~80.80μg/mL和60.75~810.00μg/mL范围内与峰面积线性良好,r分别为0.9994和0.9998,平均回收率分别为101.43%和100.70%,RSD为1.28%和1.58%(n=9)。结论HPLC法操作简便,分离效果好,灵敏度高,重现性好,为控制派瑞松乳膏质量提供了依据。Objective To establish a method for the determination of triamcinolone acetonide and econazole nitrate in Triamcinolone Ace- tonide and Econazole Nitrate Cream. Methods The Kromasil ODS- 1(200×4.6 mm) was used. The mobile phase consisted of MeOH- 0. 5%TEA(pH =3.0, HAC)(50:50). The flow rate was 1 mL/min. The UV detection wavelength was 240 nm. Results The calibration curves of triamcinolone acetonide and econazole nitrate were in good linearity over the range of 6.06-80. 80 μg/mL, 60.75-810. 00μg/mL, (r=0. 999 4, 0. 999 8), respectively. The average recovery rates were 101.43% and 100. 70%, RSD were 1.28% and 1.58% (n =9), respectively. Conclusion The method is simple, sensitive, accurate and reproducible. It can be used to control the quality of Triamcinolone Acetonide and Econazole Nitrate Cream.

关 键 词:派瑞松乳膏 曲安奈德 硝酸益康唑 高效液相色谱法 含量测定 

分 类 号:R927.2[医药卫生—药学] R986

 