摘 要:为了应对高层建筑的火灾,消防电源需要设置成独立的系统,对重要的设备设置双回路电源,且对不能停电的消防设备须自带不间断电源。很多消防电源的设计均在楼宇还没建设时已经完成,而在实际施工中将遇到许多变动,安装前需对此进行优化。对完善消防电源双回路供电系统、火灾应急系统不间断电源、楼宇消防应急电源等优化进行探讨,从而满足实际要求。The fire-fight power circuit which is expected to supply dual-loop power for fire equipments must be designed independently in high-rise buildings.Many such designs had to be rebuilt because they were completed before the buildings were accomplished.This paper discussed how to improve the designs of fire-fight power circuit and uninterruptible power supply in high-rise and how to optimize the emergency power circuit for building fire to meet practical need.