检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨剑锋[1] 谢国鸿[1] 陈文[1] 黄伟[1] 彭敏[1] 陈珣[1]
机构地区:[1]湖南省电力公司试验研究院,湖南长沙410007
出 处:《湖南电力》2010年第S1期39-40,51,共3页Hunan Electric Power
摘 要:大型轴流一次风机在并列时,待并列的风机易进入小流量、高压头的不稳定工作区域,从而引发失速、喘振。本文在分析并列时风机失速、喘振原因的基础上,提出了1 000 MW超超临界锅炉一次风机,并列技术措施并在调试中予以实施,解决了大型轴流一次风机并列的难题。When the large axial-flow primary fans are paralleling,the fan usually enters into unstable work fields(low-flow rate,high pressure).As a result speed stalling and surging occurs.The paralleling technology on the axial flow primary fans for 1 000 MW Ultra-supercritical boilers was put forward and the technology was applied successfully based on analysis of speed stalling and the surging.The problem of large axial primary fans'parallel was solved,and it was a beneficial attempt.
分 类 号:TM621.2[电气工程—电力系统及自动化]
正在载入数据...