检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]Inst.of Biomedical Instrument,Shanghai Jiaotong Univ.
出 处:《Journal of Shanghai Jiaotong university(Science)》2007年第4期537-544,共8页上海交通大学学报(英文版)
基 金:The National Natural Science Foundation ofChina (No 30500124);Shanghai Key Tech-nologies R&D Program of China ( No05DZ19509)
摘 要:A nonlinear finite-element program was developed to simulate the dynamic evolution of coagulation in tissue considering temperature and thermal-dose dependence of the ultrasound attenuation and blood perfusion rate. The effects of these dynamic parameters on the lesion formation were investigated in the particular case of ultrasound hepatic ablation with bi-focus intensity pattern. The results of simulations were compared that incorporate dynamic changes of ultrasound attenuation and perfusion and results that neglect these effects. The result shows that thermal-dose-dependent ultrasound attenuation is the dominating factor in the full dynamic model. If the dynamic ultrasound attenuation is ignored, a relatively significant underestimation of the temperature rise appears in the focal plane and the region next to the focal plane, resulting in an underestimation in predicting diameter of coagulation. Higher heating intensity leads to greater underestimation.A nonlinear finite-element program was developed to simulate the dynamic evolution of coagulation in tissue considering temperature and thermal-dose dependence of the ultrasound attenuation and blood perfusion rate. The effects of these dynamic parameters on the lesion formation were investigated in the particular case of ultrasound hepatic ablation with bi-focus intensity pattern. The results of simulations were compared that incorporate dynamic changes of ultrasound attenuation and perfusion and results that neglect these effects. The result shows that thermal-dose-dependent ultrasound attenuation is the dominating factor in the full dynamic model. If the dynamic ultrasound attenuation is ignored, a relatively significant underestimation of the temperature rise appears in the focal plane and the region next to the focal plane, resulting in an underestimation in predicting diameter of coagulation. Higher heating intensity leads to greater underestimation.
关 键 词:ULTRASOUND phased arrays finite element TEMPERATURE-DEPENDENCE thermal-dose-dependence DYNAMIC blood PERFUSION DYNAMIC ULTRASOUND attenuation
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.144.252.248