Experimental research of a thermoacoustic prime mover and a refrigerator  

Experimental research of a thermoacoustic prime mover and a refrigerator

在线阅读下载全文

作  者:DONG Kaijun, LI Qing, GUO Fangzhong (Cryogenic Laboratory, Huazhong University of Science and Technology Wuhan) 

出  处:《Chinese Journal of Acoustics》2001年第4期371-377,共7页声学学报(英文版)

基  金:the National Natural Science Foundation of China (No.59706003).

摘  要:Thermoacoustic engine has been concerned recently because of its advantages of no moving parts and no pollution. A prime mover is built and its characteristics of onset temperature difference, frequency and output acoustic power are measured and analyzed. A thermoacoustic refrigerator driven by this prime mover had been tested. It may develop a temperature difference of 25 K across the regenerator and a lowest temperature of -8℃ was achieved with the frequency, input power and the static pressure 81.7 Hz, 800 W and 1 Mpa respectively.Thermoacoustic engine has been concerned recently because of its advantages of no moving parts and no pollution. A prime mover is built and its characteristics of onset temperature difference, frequency and output acoustic power are measured and analyzed. A thermoacoustic refrigerator driven by this prime mover had been tested. It may develop a temperature difference of 25 K across the regenerator and a lowest temperature of -8℃ was achieved with the frequency, input power and the static pressure 81.7 Hz, 800 W and 1 Mpa respectively.

分 类 号:TB61[一般工业技术—制冷工程]

 