无X线定位经椎弓根螺钉脊柱内固定的探讨  

Exploration of Internal Fixation of spine Through vertebral pedicle without x-ray Location

在线阅读下载全文

作  者:安荣泽[1] 敖竣[1] 廖文波[1] 彭刚[1] 杨圣[1] 

机构地区:[1]遵义医学院附属医院外二科,563003

出  处:《实用骨科杂志》1997年第2期65-68,共4页Journal of Practical Orthopaedics

摘  要:在无X线监视下行经椎弓根螺钉脊柱内固定术48例,置钉214枚。术后X线片检查置钉位置优良149枚(69.6%),差65枚(30.4%),错0枚。作者认为熟悉椎弓根的定性定量解剖是正确置钉的基础,“盲目”置钉法对无X线监护条件的医院开展本术式有一定的实用价值。214 pedicle screwes had been inserted through vertebral pedicle without x-ray monitoring in 48 cases. Postoperative radiograph showed that position of 149 pedicle screws(69.6%)were excellent . 65 screws (30. 4%) were inferior and there was no error-Autthors suggest that familiarity with quantitative and quanlitative anatomy of vertebral pedicle should be basis of correct insertion of pedlicle screwes. 'Blind'insertion should be valuable for basic-level hospitals to practise the operation.

关 键 词:椎弓根螺钉 内固定 

分 类 号:R687.3[医药卫生—骨科学]

 