检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:任进民[1] 李杏利[2] 赵曦 郭立志[1] 刘剑[1]
机构地区:[1]河北医科大学第二医院,河北石家庄050000 [2]北京出版社教材中心,北京100088 [3]中奇制药技术有限公司,河北石家庄050051
出 处:《中国医药工业杂志》2009年第4期292-294,共3页Chinese Journal of Pharmaceuticals
摘 要:建立了LC-MS/MS法测定人血浆中格列美脲的浓度。采用C18色谱柱,以格列齐特为内标,流动相为2mmol/L乙酸铵溶液(含0.5%甲酸)-甲醇(27∶73),电喷雾离子化源,选择性正离子多反应监测,检测离子分别为m/z491.2→m/z352.0(格列美脲)和m/z324.1→m/z127.2(格列齐特)。结果格列美脲在1~400ng/ml浓度范围内线性关系良好,相对回收率大于99.1%,提取回收率大于95.7%,日内和日间RSD均小于10.1%。A LC-MS/MS method was established for the determination of glimepiride in human plasma. A C18 column was used with gliclazide as the internal standard, using 2 mmol/L ammonium acetate (containing 0.5 % formic acid)-methanol (27 : 73) as the mobile phase. ESI was applied and operated in positive iron multiple-reaction monitoring mode. The detected ions were m/z 491.2→m/z 352.0 (glimepiride) and m/z 324.1→m/z 127.2 (gliclazide). The calibration curve was linear in the concentration range of 1 - 400 ng/ml.The relative recovery was over 99.1% and the average extraction recovery was above 95.7 %, The RSDs of inter- and intra-day were less than 10.1%.