机构地区:[1]湖北工业大学土木工程与建筑学院,武汉430068 [2]廊坊市中铁物探勘察有限公司东南项目部,泉州362005
出 处:《建筑结构》2009年第3期34-36,共3页Building Structure
摘 要:结合某客运专线双线整孔简支箱梁的孔道摩阻损失试验,介绍了预应力束摩阻损失的试验方法,利用最小二乘法对测试数据进行处理,得到了摩阻损失系数μ和κ的计算公式及其实测结果。结果表明曲线梁的κ值比直线梁的大,我国桥涵施工规范关于μ值的规定过于严格,预应力损失参数μ,κ值应在正式施加预应力之前由现场试验确定,以此作为预应力混凝土结构的设计和施工的参考依据。The experimental method to determine the attrition loss of prestress wire is introduced, combining with the tube frictional resistance loss measurement of single room simple box girders in double lines of a special railway. The data are processed by the least square method, and the calculation formula for frictional factors, μ and κ, is obtained. The results show the frictional factor of curved beams is a little larger than that of straight lined beams, the fixed frictional μ in Chinese national standard is extremely strict, the frictional factors κ and μ should be determined according to the spot experiment before exerting prestress. These parameters obtained provide the foundation for the prestress concrete structure design and construction.
关 键 词:摩阻损失 预应力束 最小二乘法 摩阻系数 曲线梁
分 类 号:TU757[建筑科学—建筑技术科学] U448.21[建筑科学—桥梁与隧道工程]