检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]河南平玉县人民医院,463400
出 处:《临床心血管病杂志》1998年第2期84-85,共2页Journal of Clinical Cardiology
摘 要:目的:探讨食管心房调搏负荷试验、平板试验、潘生丁试验对冠心病的诊断价值。方法:食管心房调搏负荷试验、活动平板试验,心率达到次极量级水平,按二阶梯运动试验的方法记录心电图。潘生丁试验,潘生丁0.50~0.75mg/kg溶于5%葡萄糖液20ml中,前3min注入总量的一半、后7min注完另一半。结果:三种方法的敏感性分别为84.6%、76.9%、69.2%,特异性分别为100%、100%、95%。结论:食管心房调搏负荷试验优于活动平板试验和潘生丁试验。Objective:To find out diagnosis values of atrial pecing test,treadmill exercise test,dipyridamol test on the coronary heart disease. Methods:When heart rate achieved the level of submaximal exercise test according to Master's method, electrocardiogram was recorded in atrial pacing test and treadmill exercise test. In dipyridamol test,dissolved dipyridamol 0. 5~0.75 mg/kg in 5% glucose 20 ml.Injected 1/2 dosage of dipyridamol within first 3 minutes,the other 1/2 dosage of dipyridamol was completely injected in 7 other minutes. Results:Sensitivity of 3 cardiac loading test was respectively 84.6 %, 76.9 %, 69.2 %,specificity was respectively 100%, 100%, 95%. Conclusions:Diagnostic value of atrial pacing test superior to other 2 cardiac loading tests.
分 类 号:R541.404[医药卫生—心血管疾病] R540.47[医药卫生—内科学]