蒸压加气混凝土外墙自保温体系技术经济分析  被引量:2

Technology and Economic Analysis on Autoclaved Aerated Concrete in Self-insulation System of External Wall

在线阅读下载全文

作  者:董孟能[1] 田学春[1] 吕忠[1] 

机构地区:[1]重庆市建筑节能中心,重庆400015

出  处:《重庆建筑》2009年第4期4-6,共3页Chongqing Architecture

摘  要:蒸压加气混凝土外墙自保温技术在建筑节能中的应用越来越广泛。本文结合夏热冬冷地区重庆的实际应用情况,对加气混凝土自保温体系的节能技术和经济效益作了具体分析。结果表明:该自保温体系不但外墙热工参数指标能满足重庆50%和65%节能标准设计要求,而且还具有较好的经济效益。The method of using self-insulation Aerated concrete in external wall has been more and more practiced in recent years. This documentation has recognized the typical cold winter and hot summer factor in Local Chongqing region, in depth analysis have been carried out to such application, regarding to its energy saving efficiency and its potential economic benefit. Results have proven, that the thermal parameters of Aerated concrete self-insulation technology not only achieve the 50% and 60% of the energy saving efficiency designs requirement, but also prove to have certain economic benefit.

关 键 词:蒸压加气混凝土 外墙自保温 节能 经济分析 

分 类 号:TU761.12[建筑科学—建筑技术科学]

 