硝基苯胺类农药废水处理的研究与实践  被引量:2

Study and application of the treatment of nitroaniline pesticide wastewater

在线阅读下载全文

作  者:朱乐辉[1] 孙娟[1] 徐星[1] 朱衷榜[1] 戚伟峰[1] 

机构地区:[1]南昌大学环境科学与工程学院,江西南昌330031

出  处:《工业水处理》2009年第4期46-49,共4页Industrial Water Treatment

摘  要:采用Fenton试剂氧化-水解酸化-Biofor(一段式生物过滤氧化反应器)工艺处理硝基苯胺类农药废水。结果表明:Fenton试剂氧化CODCr去除率为73.8%,色度去除率为88.7%;水解酸化-Biofor工艺处理CODCr去除率在20%~60%,色度去除率为63.9%,在总进水CODcr≤19870mg/L、色度≤20000倍时,采用Fenton试剂氧化-水解酸化-Biofor工艺,加入适当的冷却水稀释盐分,处理后出水CODCr〈100mg/L、色度〈50倍。Fenton reagent oxidation-hydrolytic acidification-Biofor process used for treating nitroaniline pesticide wastewater is described. The results show that the removal rates of CODCr and chroma are 73.8% and 88.7% respectively by Fenton reagent oxidation; and the removal rates of CODCr and chroma are 20%-60% and 63.9% respectively by hydrolytic acidification-Biofor process. When the total influent CODCr and chroma are ≤ 19 870 mg/L and ≤ 20 000 times, respectively. Fenton reagent oxidation-hydrolytic acidification-Biofor process is used, adding adequate cooling water to dilute salinity. After the treatment, the CODCr of effluent is less than 100 mg/L and the chroma is less than 50 times.

关 键 词:硝基苯胺类农药废水 FENTON试剂 水解酸化 一段式生物过滤氧化反应器 

分 类 号:X703.1[环境科学与工程—环境工程]

 