检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《电力自动化设备》2009年第5期126-129,共4页Electric Power Automation Equipment
摘 要:结合某500 kV变电站无人值班科技项目研究,提出了500 kV变电站远方集中监控系统应该满足安全、可靠、实时、先进等要求,维护要求简单方便。认为监控系统的建设模式可优先采用调度系统与集控系统一体化建设。系统采用功能分布式设计和全网络结构,双重化冗余配置,应用软件按功能发布在各台服务器和工作站。集控系统功能应用软件包括基本SCADA软件和监控管理、处理软件。论述了适应500 kV变电站无人值班的技术措施(程序化操作票传送、保护管理功能集成、责任分区及信息分层/分流、实时信息分析告警)等。For a 500 kV unmanned substation project, the centralized remote monitoring system is presented, which meets the requirements of security, reliability, real-time performance, high-technology and easy -maintenance. The construction mode of integrative system of power dispatch automation and centralized control is suggested, which adopts the design of distributed functions, the structure of total network and the redundant configuration. The application software are distributed among servers and workstations according to functionalities, including basic SCADA, monitoring management and processing software. The technical procedures suitable for 500 kV unmanned substation are discussed in terms of programmed operation ticket delivery, protection management function integration, responsibility division, hierarchical and distributed information flow, real-time information analysis and alarm, etc..
关 键 词:500 KV变电站 集中监控系统 信息分层分流 保护集成 程序化操作
分 类 号:TM73[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.121