Experimental and theoretical study on vibration control of base-isolation with energy transducer  被引量:2

Experimental and theoretical study on vibration control of base-isolation with energy transducer

在线阅读下载全文

作  者:程树良 辛亚军 王焕定 

机构地区:[1]School of Civil Engineering and Mechanics, Yanshan University [2]School of Civil Engineering, Harbin Institute of Technology

出  处:《Journal of Harbin Institute of Technology(New Series)》2009年第2期165-171,共7页哈尔滨工业大学学报(英文版)

基  金:Sponsored by the Hebei Scientific and Technological Research and Development Plans (Grant No.07215615)

摘  要:In order to evaluate the effects of structural control and energy transition for the base-isolation with energy transducer (BIET), shaking table tests on a steel frame model (BIET system) with scale of 1:4 were conducted and the results were compared with the lead rubber beating (LRB) isolation system for the same model. Then numerical analysis of the system was carried out, in which the improved Wen analytic model was used to simulate the hysteretic law of transducers. The results show that the structural system can transform the partial earthquake energy to hydraulic energy ; furthermore, the effect of structural control can reach or be close to that of the LRB isolation system. The agreements between numerical analysis results and those of shaking table tests demonstrate the accuracy of the numerical model.In order to evaluate the effects of structural control and energy transition for the base-isolation with energy transducer (BIET), shaking table tests on a steel frame model (BIET system) with scale of 1:4 were conducted and the results were compared with the lead rubber bearing (LRB) isolation system for the same model. Then numerical analysis of the system was carried out, in which the improved Wen analytic model was used to simulate the hysteretic law of transducers. The results show that the structural system can transform the partial earthquake energy to hydraulic energy; furthermore, the effect of structural control can reach or be close to that of the LRB isolation system. The agreements between numerical analysis results and those of shaking table tests demonstrate the accuracy of the numerical model.

关 键 词:base-isolation with energy transducer (BIET) structural control shaking table test hysteretic law numerical analysis 

分 类 号:TU352.12[建筑科学—结构工程] TP212[自动化与计算机技术—检测技术与自动化装置]

 