检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李书纲[1] 盛林[1] 赵宏[1] 仉建国[1] 翟吉良[1] 朱勇[1]
机构地区:[1]中国医学科学院北京协和医院骨科,北京市100730
出 处:《中国组织工程研究与临床康复》2009年第17期3365-3369,共5页Journal of Clinical Rehabilitative Tissue Engineering Research
摘 要:背景:近年来经椎弓根螺钉固定技术显著提高了脊柱固定强度和融合效率,但是椎弓根螺钉置入位置不佳可能损害脊髓和神经引起严重并发症。目的:评估置入前CT扫描三维虚拟图像导航技术在脊柱椎弓根螺钉固定中的应用价值。设计、时间及地点:前瞻性、随机对照观察,于2006-01/2008-12在中国医学科学院北京协和医院骨科完成。对象:纳入因脊柱疾病行椎弓根螺钉固定的患者 95 例,导航组45例,常规组50例。方法:将95例患者按随机数字表法分为 2组,导航组术中在计算机导航技术辅助下置入椎弓根螺钉,常规组采用传统的解剖标志法结合术中透视定位置入椎弓根螺钉。主要观察指标:比较 2 组间螺钉钉道准备时间、螺钉位置优良率及螺钉置入后并发症的发生率。结果:导航组中36例患者共置入椎弓根螺钉 206 枚,优良率 96.1%;有 9 例患者因故未能行导航。常规组 50 例患者共置入椎弓根螺钉 285 枚,优良率 100.0%,无位置差的螺钉。2组患者的螺钉位置优良率差异无显著性意义(P>0.05)。导航组的钉道准备时间显著长于常规组[(360±22),(56±8) s,P<0.01]。组患者螺钉置入后均无并发症发生。2结论:与传统解剖标志定位法相比,应用置入前CT扫描三维虚拟图像导航技术置入椎弓根螺钉的精度无明显差异,且延长了手术时间,其在脊柱椎弓根螺钉固定中的应用价值有限。BACKGROUND: Recently, trans-pedicle screw internal fixation has markedly improved the rigidity of spinal fixation and hence the fusion rate. But when placed incorrectly, the pedicle screw can injure the spinal cord and/or nerve roots, resulting in serious complications. OBJECTIVE: To evaluate the application value of preoperative CT scans-based navigation technique in the spinal pedicle screw internal fixation surgery. DESIGN, TINE AND SETTING: A prospective, randomized, and controlled observation was performed at the Department of Orthopedics, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences between January 2006 and December 2008. PARTICIPANTS: A total of 95 patients who underwent pedicle screw internal fixation due to spine diseases were randomly assigned to a navigation group (n = 45) and a conventional group (n = 50). METHODS: In the navigation group, patients were subjected to pedicle screw insertion with the assistance of computer navigation technique and while in the conventional group, patients underwent pedicle screw insertion using the conventional anatomic landmark combined with fluoroscopy. MAIN OUTCOME MEASURES: Screw channel preparation time, excellent and good rate of screw position, and postoperative complications. RESULTS: In the navigation group, totally 206 pedicle screws were inserted under navigation guidance, with an excellent and good rate of 96.1%; and navigation could not be continued in 9 patients for a three-dimensional registration error. In the conventional group, altogether 285 pedicle screws were inserted, and the excellent and good rate was 100%, No significant difference was found between the two groups (P 〉 0.05). The navigation group exhibited longer screw channel preparation time than the conventional group [(360±22) seconds vs. (56±8) seconds, P 〈 0.01]. No postoperative complications were found in each group. CONCLUSION: The preoperative CT scans-based navigation technique produces similar accuracy of pedicle
分 类 号:R318[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30