钢管混凝土抗剪连接件的试验研究  被引量:19

Experimental Study on Shear Connectors of ConcreteFilled Steel Tube

在线阅读下载全文

作  者:薛立红[1] 蔡绍怀[1] 

机构地区:[1]中国建筑科学研究院建筑结构研究所

出  处:《建筑科学》1998年第1期13-21,共9页Building Science

基  金:国家自然科学基金;建设部资助

摘  要:为了保证钢管混凝土梁柱节点剪力的可靠传递,常需在钢管内设置抗剪连接件。钢板环、钢筋环和钢筋钉抗剪连接件具有传力明确、不妨碍混凝土浇灌的优点。为了查明抗剪连接件的工作特点,本文进行了18个在钢管内焊接钢板环、钢筋环、钢筋钉抗剪连接件的钢管混凝土推出试验。根据试验结果确定了连接件的计算公式并对连接件的构造提出了相应的建议。In order to transfer the shear force at the beamcolumn connection in concretefilled steel tubular structures reliably,shear connectors are often used in steel tube.Shear connectors of steel platering,barring and barnail have advantages of transferring loads clearly and not hindering from pouring concrete.To find out the mechanical behavior of the shear connectors,18 pushout tests of concretefilled steel tubes with shear connectors of steel platering,barring and barnail were carried out in our Academy.A formula for predicting the strength of shear connectors and their construction detail are presented in the paper.

关 键 词:钢管混凝土结构 试验 抗剪连接件 

分 类 号:TU398.903[建筑科学—结构工程]

 