作 者:邹碧珍[1] 李新玉[1] 韩美丽[1] 敬德仲 王淑华[1] 曲杰[1]
机构地区:[1]黑龙江省科学院应用微生物研究所,哈尔滨150010
出 处:《生物技术》1998年第1期29-32,共4页Biotechnology
摘 要:本文叙述了试剂盒的制备和考核的全过程,试剂盒用6个国际标准株、46个淋球菌临床株、32株不动杆菌和51株非淋球菌临床株对其敏感性、特异性进行了考核,并同革兰氏染色法和细菌培养法作了平行对比试验,结果表明本试剂盒具有敏感(O.3亿/ml)、特异(100%)、快速(3min)的特点.三种方法的比较研究证明革兰氏染色法的准确率为95.6%,培养法和试剂盒的准确率均为100%;与培养法的符合率革兰氏染色法为95.6%,试剂盒为100%.This paper related the whole process of preparation ano cneck of the Diagnosis Kit for Gomorrhea the Diagnosis Kit was checked to its sensitivity and specificity. The parallel con-trast test with Gram Stainitn method and Bacteria Culture method has been carried on , The results indicated that the Diagnosis Kit has the characteristics of sensitivity, specificity and repaidity. The accuracy cf Gram Stainint method. Bacteria Culture method and the Diagnosis Kit is 95. 6%、100%、100%、respectively.
分 类 号:R759.205[医药卫生—皮肤病学与性病学]