TBB-800-2EY3型汽轮发电机定子端部绕组故障与结构弊病分析  被引量:5

Analysis of stator end winding fault and constructional defect for the design of TBB-800-2EY3 turbo-generator

在线阅读下载全文

作  者:王绍禹 孙术文[2] 韩长利[2] 刘文忠[2] 

机构地区:[1]东北电力科学研究院,辽宁沈阳110006 [2]国华绥中发电有限责任公司,辽宁绥中125222

出  处:《中国电力》2009年第5期35-40,共6页Electric Power

摘  要:绥中发电有限公司的2台俄罗斯电力工厂制造的TBB-800-2EY3型汽轮发电机运行约19000h,出现由于定子线棒振动引起的股线磨损断裂以及定子端部绕组连接母线振动导致疲劳断裂的故障。分析认为定子端部绕组支撑刚度严重不足、整体性差等设计结构上的弊病是造成该型发电机故障的根本原因,定子端部铜屏蔽位置设置不当,造成损耗大、温升高是限制发电机进相运行能力的起因。对该型汽轮发电机定子端部绕组支撑结构及铜屏蔽结构的现代化改造提出了具体建议。The fault occurred on two TBB-800-2EY3 turbo-generators was described, they were manufactured by Russian (Electrosila) Factory, running around 19 000 h in Guohua Suizhong Power Plant. Vigorous vibration of stator winding bars caused strand wear, fracture, and fatigue fracture of connection on parallel ring. The fault of the generator was caused by the structure design, such as the poor stiffness of stator end-winding support and the lacking compactedness of stator end-winding. The imperfect arrangement of core end plate cooper screen will cause the loss increase and temperature rise, which is also the cause of lower the leading phase operation capability of the generator. The suggestions for modernization reformation of stator end winding supporting construction and core end plate cooper screen structure arrangement were presented.

关 键 词:定子端部绕组 端部绕组支撑 振动 磨损 断裂故障 

分 类 号:TM311[电气工程—电机]

 