液氦温区G-M型制冷机P-V图实验测试系统的建立及结果  

Measurement Apparatus of the P-V Diagram of a 4.2 K G-M Refrigerator

在线阅读下载全文

作  者:张智勇[1] 刘景忠[1] 徐向东[1] 王莉[1] 张亮[1] 

机构地区:[1]中科院低温技术实验中心

出  处:《低温与超导》1998年第1期19-25,共7页Cryogenics and Superconductivity

基  金:国家自然科学基金

摘  要:建立了一套液氦温区G-M型制冷机P-V图测试系统,测试装置主要包括制冷机进、排气和冷、热腔压力的压力测量系统及制冷机活塞位移的测量系统。该系统将制冷机动态压力、动态位移的测量信号通过采集系统送入微机中进行处理,可实时绘制压力及P-V图图形曲线,随时掌握不同结构不同工况下G-M制冷机压力损失和P-V图效率情况,为制冷机性能的改进、制冷机的理论分析及设计计算提供了可靠的实验依据。通过测试系统,测试了制冷机冷腔在不同制冷温度下的P-V图效率,指出在深低温区冷腔P-V图面积并不代表制冷机实际制冷量。A measurement system of the P-V diagram of a 4.2 K G-M refrigerator is established in this paper. The pressure curves vs. time of the 2nd stage cold space, admission line and exhaust line of the 4.2 K G-M refrigerator and the P-V diagram of the 2nd stage cold space can be obtained by the measurement system. By comparing the P-V diagram efficiency with the ideal and real cooling capacities, it was indicated that the increased P-V diagram area at low temperature (<8 K or so) doesn't represent the net increased cooling capacity. In addition, the pressure drops in the admission line and exhaust line greatly increase with the cooling temperature decreasing.

关 键 词:G-M型 制冷机 P-V图 测试系统 液氦 