摘  要:T4、T5荧光灯是新型高效节能光源,但是它配套的电子镇流器支架早期损坏率较高影响了其推广,对收集的损坏样品的统计分析表明,T4、T5荧光灯电子镇流器设计存在"误用"元件问题,经试验提出了设计改进建议。T4/T5 fluorescent lamp is a new light source with high efficiency. But the higher failure rate at early period of the electronic ballast for the lamp affects its popularity. The statistic analysis of collected samples which failed at early period shows that the design of electronic ballast for T4/T5 fluorescent lamp has the problem of component "miss use". Therefore, this paper puts forward some proposals to improve the electronic ballast with experiment.