检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘荣桂[1] 王正滨[1] 冉张申[2] 王德伟[2] 李翔[1] 王建红[1]
机构地区:[1]青岛大学医学院附属医院超声科,山东青岛266003 [2]泰山医学院附属医院超声科,山东泰安271000
出 处:《中国医疗设备》2009年第5期120-122,共3页China Medical Devices
摘 要:目的探讨应用高频超声和低频超声显像诊断急性阑尾炎的价值和其测量准确性。方法急性阑尾炎患者60人,超声显像检查阑尾的大小、形态、阑尾壁的厚度、阑尾腔有无扩张、有无粪石、周围有无积液等;彩色多普勒血流显像(CDFI)观察阑尾壁的血流分布情况,高频超声显像测量阑尾的直径,低频超声显像测量阑尾的长度,与手术结果相对照,并作相关分析。结果与术中测值比较,高频超声显像能较准确地显示和测量阑尾直径(P>0.05),低频超声显像测量阑尾长度与术中测值误差较大(P<0.01),但相关性较好。结论高频和低频超声联合应用观察测量阑尾的大小,测值较准确,诊断价值较高。Objective To study the value of high and low frequency ultrasound in patients with acute appendicitis. Methods 60 cases suspected acute appendicitis were examined and diagnosed by high frequency associated with low frequency ultrasound. All the cases were testified by surgery and pathology. The diameter and the length of appendixes were measured by high and low frequency ultrasound respectively. The value was compared with the measurement of surgery. Results The high frequency ultrasound could distinctly display and accurately measure the diameter of affected appendix. There was no significant difference on diameter measured by high frequency ultrasound and surgery(P 〉 0.05). The length measured by low frequency ultrasound was lower than the measurement of surgery (P〈 0.01). Conclusion High frequency associated with low frequency ultrasound can accurately measure the size of affected appendix and has high value in diagnosis of acute appendicitis.
分 类 号:R445.1[医药卫生—影像医学与核医学]