柴油加氢装置循环氢压缩机气阀故障原因分析及解决方法  

Diesel hydrotreating recycle hydrogen compressor valve device failure analysis and solutions

在线阅读下载全文

作  者:韩莉[1] 王为民[1] 王艳东 张建新 

机构地区:[1]辽宁石油化工大学储运与建筑工程学院,抚顺113001 [2]中国石油新疆独山子石化分公司,新疆833600

出  处:《机械设计与制造》2009年第6期265-266,共2页Machinery Design & Manufacture

摘  要:环氢压缩机气阀故障的原因,针对影响压缩机气阀安全运行的瓶颈,采取一系列行之有效的措施,降低了柴油加氢装置循环氢压缩机气阀检修频次,确保了装置安全平稳运行。Have analysed the cause of air valve malfunction in circulation hydrogen compression engine for diesel oil hydrogenation from June in 2006 to March in 2007 ,and have adopted a series of effective measure specifically for affecting the working safe compression engine air valve bottleneck,and have reduced the examining and repairing frequency of circulation hydrogen compression engine air valve in diesel oil hydrogenation unit, and have ensured that device operates safety and stably.

关 键 词:往复式压缩机 气阀 脱液 