油田联合站能耗“三环节”评价  被引量:1

Three-link Evaluation on Energy Consumption of Oilfield United Station

在线阅读下载全文

作  者:冯国栋[1] 朱玉泉[2] 

机构地区:[1]中国石化胜利油田分公司技术检测中心,山东东营257000 [2]中国石油大学(北京)机电学院,北京102249

出  处:《节能技术》2009年第3期212-215,共4页Energy Conservation Technology

摘  要:本文应用"三环节"能量结构理论,将油田联合站的工艺过程用能分为能量的转换和传输环节、工艺利用环节和能量的回收环节进行评价,得到各个环节的效率,以胜利油田东辛102联合站为例,得出东辛102联合站能量回收环节效率仅有10.6%,为效率最低环节。与实际一致的分析说明了三环节理论的科学性。Based on the three - link energy structure theory, enery consumption in oilfield united station energy utilization process is analysed from the points of energy utilization and transformation link, process energy consumption link and waste energy recovery link, and energy utilization efficiency data every link of can be deferminated carefully. Taking Dongxin 102 oilfield united station for the evaluating object, authors concluded that the least efficient link is the united station waste energy recovery, its energy utilization efficiency is only 10.6%. Agreement between anlysis and actual data suggested that three - link theory is suitble for energy consumption evaluation of oiffield united station. oiffield united station; energy consumption; three - link; evaluation

关 键 词:油田联合站 能耗 三环节 评价 

分 类 号:TM461[电气工程—电器]

 