检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:盛荣[1] 李文新[1] 朱明花[1] 何蔚瑜[1] 尹端止[1] 胡伟青[1]
机构地区:[1]中国科学院上海原子核研究所
出 处:《核化学与放射化学》1998年第2期109-113,共5页Journal of Nuclear and Radiochemistry
基 金:国家自然科学基金
摘 要:以酸性氧化铝为吸附剂,制备了一个118MBq的188W-188Re发生器,并对发生器性能进行了为期4个月的检测。结果表明,188Re的淋洗产额在80%—90%之间,188W的穿透率约为1.0×10-4%。由于采用了较大高径比的交换柱,使188Re的放射性比活度较高,能满足用于放射免疫治疗研究的抗肿瘤单克隆抗体标记的要求。An alumina based 188 W 188 Re generator,containing 188 MBq (3.2 mCi) 188 W,has been prepared.Performance of the generator has been evaluated for four months.The results indicated that the 188 Re yields of elution with physiological saline decreased from approximately 90% to around 80% and the breakthrough of the parent 188 W is about 1×10 -4 %.Due to the higher ratio of height to diameter of the chromatographic column employed in the work,higher specific acitivity of the 188 Re from the generator can meet the requirements of labeling monoclonal antibodies for radioimmunotherapy.