某工程火灾后安全性鉴定及修复加固  被引量:3

Safety Appraisal and Strengthening for a Building After Fire

在线阅读下载全文

作  者:翟传明[1] 代伟明[2] 王巍[2] 肖伟[2] 

机构地区:[1]国家建筑工程质量监督检验中心,北京100013 [2]建研科技股份有限公司,北京100013

出  处:《施工技术》2009年第6期67-69,共3页Construction Technology

摘  要:某工程地下2层、地上12层,为框架剪力墙结构。于2008年1月发生火灾,过火面积约60 000m2,火灾持续时间约60h,火灾后立即进行了检测鉴定及加固修复处理,8层以上由于损坏严重,需要拆除重建,7层以下采取整体加固的处理方法。通过现场检测,对结构构件的受损程度及结构安全性进行分级,对不同等级的受损构件提出相应的修复加固措施。Same building with 12 floors above ground level and 2 floors basement is frame-shear wall structure, and it was in fire for 60 hours on January, 2008 and burned areas are about 60 000m^2. This building was tested and repaired immediately by strengthening. One part above floor 8 is demolished because of serious damage, the others need to be strengthened. By on-site detection, construction members are graded by damaged degree and safety, corresponding repairing measures are put forward by member grade.

关 键 词:钢筋混凝土结构 火灾 鉴定 加固 

分 类 号:TU746.2[建筑科学—建筑技术科学]

 