系统不明泄漏对常规热力性能试验中煤耗指标影响分析  被引量:1

Analysis of the Impact of Unaccounted-for Leakage of System on Calculating Coal Consumption in the Thermal Performance Conventional Test

在线阅读下载全文

作  者:郭江龙[1] 张春雷[2] 刘叶丽[2] 刘文献[1] 

机构地区:[1]河北省电力研究院,石家庄050021 [2]河北建投能源投资股份有限公司,石家庄050051

出  处:《汽轮机技术》2009年第3期229-230,238,共3页Turbine Technology

基  金:河北省电力公司2008年度科技项目;项目编号:KJ2008-041

摘  要:全面定性分析系统不明泄漏对煤耗指标计算的影响,指出综合考虑系统不明泄漏对汽轮机热耗率、锅炉效率和管道效率三者的影响,能够最大限度的弱化试验人员通过主观分配系统不明泄漏在炉侧分配比例的方式"主导"煤耗计算结果,有利于常规热力性能试验中客观评价机组能耗水平。实例验证了方法的可行性。A comprehensively qualitative analysis of the unaccounted - for leakage of system used in the coal consumption calculation is given. It is pointed out that comprehensively analyzing the effect to heat rate, boiler efficiency and pump efficiency caused by the unidentified leakage of system, can weaken the coal consumption calculation result to the maximum limit, which is dominated by testing engineer subjectively assigning the distribution proportion of the unidentified leakage of system. It is beneficial to the objective evaluation of energy consumption in the thermal performance conventional test. An example shows that it is feasible.