生物膜法A/O系统处理化纤废水中试研究  

Study of Chemical Fiber Waste Water Treatment in Pilot Plant with Biological Film Technique A/O System

在线阅读下载全文

作  者:宋海玉[1] 王薇[1] 张春燕[1] 

机构地区:[1]大庆石油化工总厂腈纶厂

出  处:《黑龙江石油化工》1998年第2期43-45,共3页Heilongjiang Petrochemical Technology

摘  要:采用生物膜法A/O(缺氧/好氧)系统处理化纤废水的试验结果表明,该系统处理化纤废水不但对COD、氰化物有较强的降解能力,而且对氨氮和总氮也有较好的去除效果。在缺氧段与好氧段的容积比为1:3,硝化液回流比为3:1,系统水力停留时间为47h时,生物膜法A/O系统对化纤废水氨氮的去除率超过90%,总氮和COD的去除率分别达到80%和90%以上。The experiment result of treating chemical fiber waste water with biological film technique A/O system shows that treating chemical fiber waste water with this system not only has stronger degradability to COD and cyanides, but also has better result of ammonia/nitrogen and total nitrogen removal.The volumetric ratio of anaerobic section /aerobic section is 1:3, the reflux ration of nitrate solution is 3:1, the system hydraulic residence time is 47 hrs. Ammonia/nitrogen removal rate form chemical fiber waste water with biological film technique A/O system is above 90%,removal rate of total nitrogen and COD reaches to 80% and above 90% separately.

关 键 词:化纤废水 脱氮 生物膜地 A/O系统 废水处理 

分 类 号:X740.3[环境科学与工程—环境工程]

 