Deadbands and the Dynamic Response and Performance of Large Water Transfer Canal System  被引量:2

Deadbands and the Dynamic Response and Performance of Large Water Transfer Canal System

在线阅读下载全文

作  者:DING Zhiliang WANG Changde TAN Guangming GUAN Guanghua 

机构地区:[1]State Key Laboratory of Water Resources and Hydropower Engineering Science, Wuhan University, Wuhan 430072, China

出  处:《Journal of Northeast Agricultural University(English Edition)》2009年第2期58-65,共8页东北农业大学学报(英文版)

基  金:Supported by the National Natural Science Foundation of China (59879016);The Key Projects in the National Science & Technology Pillar Program during the 11th Five-Year Plan Period of China (2006BAB04A12)

摘  要:An operating simulation mode for multireach canal system in series under gate regulating is established. The discharge feedforward plus water lever feedback PID controller was adopted. And the performance indicators are introduced to evaluate the control effects of canal operation. Influence on dynamic response process and dynamic performance as well as the control actions of canal system are studied according to the variation of the gate deadband and water level deadband. The results showed that the larger the gate deadband, the worse, the control effect of canal system over water level, and so done the stable process of gate discharge, yet the stable process of gate opening was getting better, while the upstream gate regulation of each canal pool was less at the time when canal stabilizes; the closer to downstream end of canal, the lager steady-state error of this canal pool was, and the lager influence of gate deadband on the steady-state error as well as response time of this canal pool was; the canal system can not acquire superiority in both the control performance and control actions when only the water level deadband was established.An operating simulation mode for multireach canal system in series under gate regulating is established. The discharge feedforward plus water lever feedback PID controller was adopted. And the performance indicators are introduced to evaluate the control effects of canal operation. Influence on dynamic response process and dynamic performance as well as the control actions of canal system are studied according to the variation of the gate deadband and water level deadband. The results showed that the larger the gate deadband, the worse, the control effect of canal system over water level, and so done the stable process of gate discharge, yet the stable process of gate opening was getting better, while the upstream gate regulation of each canal pool was less at the time when canal stabilizes; the closer to downstream end of canal, the lager steady-state error of this canal pool was, and the lager influence of gate deadband on the steady-state error as well as response time of this canal pool was; the canal system can not acquire superiority in both the control performance and control actions when only the water level deadband was established.

关 键 词:canal operation deadband PID controller performance indicator dynamic response dynamic performance 

分 类 号:TP273[自动化与计算机技术—检测技术与自动化装置] TV146[自动化与计算机技术—控制科学与工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象