内冷式窗玻璃冷却性能分析  

THE COOLING ABILITY OF INTERNALLY COOLED WINDOW

在线阅读下载全文

作  者:桂业伟[1] 宁勇[1] 贺立新[1] 

机构地区:[1]中国空气动力研究与发展中心总体技术部,绵阳621000

出  处:《工程热物理学报》1998年第2期224-227,共4页Journal of Engineering Thermophysics

摘  要:In this paper, the cooling ability of internally Cooled IR Window is numerically studied.The temperature distribution is obtained from unsteady heat conduction equation. It is foundthat the number of cooling holes in the IR window is the most important factor to the coolingability in the case of keeping the same transparent area. The temperature is sensitive theheight of the cooling hole when the height is shorter. Radiation effect on the temperature ofthe window may be neglected. In conclusion, the temperature of IR window can be keepedat proper value by internal cooling.In this paper, the cooling ability of internally Cooled IR Window is numerically studied.The temperature distribution is obtained from unsteady heat conduction equation. It is foundthat the number of cooling holes in the IR window is the most important factor to the coolingability in the case of keeping the same transparent area. The temperature is sensitive theheight of the cooling hole when the height is shorter. Radiation effect on the temperature ofthe window may be neglected. In conclusion, the temperature of IR window can be keepedat proper value by internal cooling.

关 键 词:冷却 温度 数值计算 窗玻璃 内冷式 飞行器 

分 类 号:V250.3[一般工业技术—材料科学与工程] V254.2[航空宇航科学与技术—航空宇航制造工程]

 