负荷(F/M)对A^2/O工艺脱氮影响的研究  被引量:7

INFLUENCE OF BOD_5 LOADING (F/M) ON NITROGEN REMOVAL IN A^2/O PROCESS

在线阅读下载全文

作  者:赵丰[1] 戴兴春[1,2] 黄民生[1] 朱勇[1] 林剑波[1] 

机构地区:[1]华东师范大学资源与环境科学学院,上海200062 [2]江苏省仪征市水务局,江苏仪征211400

出  处:《水处理技术》2009年第7期59-63,共5页Technology of Water Treatment

基  金:上海市建委2007年重大科技攻关项目<城市污水处理升级改造工艺技术>(2007007)

摘  要:以上海市白龙港城市污水厂初沉池污水为进水,构建A2/O试验系统。调节试验系统有机负荷(F/M),并分析负荷对A2/O工艺脱氮的影响。结果表明,COD去除最佳F/M范围为0.14~0.28gBOD5·gMLSS-1·d-1;BOD5去除最佳F/M范围为0.14~0.22gBOD5·gMLSS-1·d-1;反硝化最佳F/M范围为0.13~0.23gBOD5·gMLSS-1·d-1;硝化最佳F/M范围为0.14~0.28gBOD5·gMLSS-1·d-1。根据分析,F/M介于0.14~0.22gBOD5·gMLSS-1·d-1之间时,A2/O工艺脱氮效果最佳。The original water of Bailonggung wastewater treatment plant was used to construct A^2/O process,The influence of F/M on nitrogen removal was studied by regulating the BOD5 loading (F/M) of A2/O process. The results showed that the best range of F/M for COD remove was 0.15-0.28 gBOD5·gMLSS^-1·d^-1; the best range of F/M for BOD5 remove was 0.14-0.22 gBOD5·gMLSS^-1·d^-1;the best range of F/M for denitriflcation was 0.13 0.23 gBOD5·gMLSS^-1·d^-1. the best range of F/M for nitrification was 0.14-0.28 gBOD5·gMLSS^-1·d^-1. According the analyse,the best range of F/M for the A^2/O system was 0.14-0.22 gBOD5·gMLSS^-1·d^-1.

关 键 词:A2/O工艺 脱氮 负荷 

分 类 号:X703.1[环境科学与工程—环境工程]

 