检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郝蕴琦[1] 李海宁[1] 杨坤[1] 孔鹏[2] 苏磊[1] 李俊丰[1] 陈镇平[1]
机构地区:[1]郑州轻工业学院技术物理系,河南郑州450002 [2]西安应用光学研究所,陕西西安710065
出 处:《应用光学》2009年第4期626-630,共5页Journal of Applied Optics
基 金:郑州轻工业学院校内基金支持项目
摘 要:提出了基于偏振分束法的法拉第镜偏振旋转角的测量方法。利用非偏振分束器改变法拉第镜出射光的方向,偏振分束器将该出射光分为p光和s光,分别测量其光强,应用后续"差除和"信号处理方案消除光源波动的影响,推导出法拉第镜偏振旋转角的理论表达式。分析了起偏器的消光比非0及起偏角误差对输出结果的影响,分别是0.05729°和-0.1000°。实验验证了该方法的可行性,重复测量结果为89.68°,均方值为0.01493。The measurement of polarization rotary angle for faraday mirror based on polarizationbeam-splitter was proposed. The orientation of through a non-polarized beam splitter (NPBS). the light from the faraday mirror was changed With a polarized beam splitter (PBS), the light reflected from NPBS was split into S light and P light. Their intensities were measured, and the theoretical expression of rotary angle was deduced after the impact of optical fluctuation is eliminated by signal processing. The influence of non-zero extinction ratio and polarized-angle error on output results was analyzed. Finally the intensities were repeatedly measured, and the average rotary angle was 89. 68°, the mean square deviation of all the experimental data was 0. 014 93.