检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李辉[1] 陈晓明[1] 刘广宽[1] 皇甫德银[1] 李伟[1]
出 处:《华南地震》2009年第2期49-53,共5页South China Journal of Seismology
基 金:江苏省地震局青年基金(200604)
摘 要:i角误差的大小和稳定是保证水准测量精度的一个重要条件,在实际观测中发现,DiNi12数字水准仪的i角误差不稳定,有随温度的升高而变化的趋势。通过对不同温度下的i角误差的观测,积累一定的观测数据,找出i角误差的变化规律,并采取多种措施最大限度减小i角误差对观测资料的影响,提高观测精度。It is discovered in the actual observations that the Angle i error of DiNi12 Digital Leveller is unstable and changeable and has the trend of changing with the rise of temperature. The magnitude and stability of Angle i error is one important condition to guarantee the precision of level measurement. Through observation of Angle i errors under different temperatures, accumulating observation data, finding out the changing pattern of Angle i errors and finally taking various kinds of measures, the influence of Angle i error on observation data is reduced to the maximum extent and the precision of observation is increased.
关 键 词:DiNi12数字水准仪 I角 误差 温度
正在载入数据...